Back to top
Industrial Electrical Power Transformer

Industrial Electrical Power Transformer

2500000 INR/Piece

Product Details:

  • Load Loss 5.85 kW (typical at rated load)
  • Voltage Booster Type Off-circuit tap changer (OCTC)
  • Operating Temperature -10C to 45C
  • Capacity 1600 kVA
  • Low Voltage 415 V
  • Coil Material Electrolytic copper
  • Dimension (L*W*H) 2200 mm x 950 mm x 1800 mm
  • Click to View more
X

Industrial Electrical Power Transformer Price And Quantity

  • 2500000 INR/Piece
  • 1 Piece

Industrial Electrical Power Transformer Product Specifications

  • High-grade silicon steel, copper windings
  • Three Phase
  • 1600 kVA
  • -10C to 45C
  • 415 V
  • Toroidal/Layer Wound
  • Electrolytic copper
  • 2200 mm x 950 mm x 1800 mm
  • 50 Hz
  • Approx. 2200 kg
  • Electrical Power Transformer
  • Off-circuit tap changer (OCTC)
  • 5.85 kW (typical at rated load)
  • Based on rated capacity
  • ONAN (Oil Natural Air Natural)
  • 11 kV / 0.415 kV
  • Two or more (primary and secondary)
  • 98%
  • Up to 2500 kVA
  • Industrial electrical power distribution
  • Up to 11,000 V

Product Description

Product Details:

Type Electrical Power Transformer
Cooling Type Air Cooled
Phase 3-Phase
Mounting Type Ground Floor
Winding Material Copper
Country of Origin Made in India


We H. D. Transformer is one of the finest manufacturer of all kind of transformer such as Three Phase, Oil Cooled, Dry Type, Cast Resin, Substation etc. We are delivering it to accross the world.
Send us your buying requirements and we would glad to serve you.

Reliable and Efficient Power Distribution

This transformer is designed to ensure steady and reliable power distribution in industrial settings, supporting high demands with robust insulation and superior efficiency. The ONAN cooling system manages temperatures effectively, while the advanced winding structure minimizes losses and optimizes output. The transformer is equipped with safety features and adheres strictly to IS and IEC standards, making it a dependable choice for varied industrial installations.


Customizable Features for Diverse Applications

Options such as Off Circuit or On Load Tap Changers (OCTC/OLTC) allow for voltage regulation per your operational needs. Multiple mounting typeswheel or skid baseensure flexibility in installation. Durable construction, anti-corrosive coating, and ambient temperature management up to 50C extend service life and reliability, even in harsh environments. The three limb core and copper windings ensure energy efficiency and consistent performance.


Quality and Compliance Assured

Manufactured using high-grade materials like silicon steel and electrolytic copper, each transformer undergoes routine and type testing as per IS 1180 and IEC 60076 standards. Protection features like Buchholz relay, oil and winding temperature indicators, PRV, and silica gel breather enhance operational safety. Quality control, comprehensive testing, and proven engineering processes ensure compliance and performance you can trust.

FAQs of Industrial Electrical Power Transformer:


Q: How is the transformer cooled during operation?

A: The transformer utilizes an ONAN (Oil Natural Air Natural) cooling system, where oil circulates naturally within the transformer to dissipate heat, and the surrounding air cools the oil. This method ensures effective temperature management, promoting longer service life and operational stability in industrial environments.

Q: What tap changer options are available and when are they used?

A: This transformer can be supplied with either an Off Circuit Tap Changer (OCTC) or an On Load Tap Changer (OLTC), depending on the application requirements. OCTC is adjusted when the transformer is de-energized, suitable for steady load scenarios, while OLTC allows for voltage regulation under load, ideal for fluctuating supply conditions.

Q: What protection devices are integrated for safety?

A: Integrated protection features include a Buchholz relay, Oil Temperature Indicator (OTI), Winding Temperature Indicator (WTI), Pressure Relief Valve (PRV), and a silica gel breather. These devices provide real-time monitoring and safeguard the transformer against faults like excessive temperature, pressure, and moisture, reducing the risk of downtime.

Q: Where is this transformer typically used?

A: This transformer is primarily used in industrial power distribution networks across manufacturing plants, large commercial facilities, and infrastructure projects in India. Its robust design and compliance with stringent standards make it suitable for demanding industrial environments that require reliable and efficient power delivery.

Q: What is the process for routine and type testing of these transformers?

A: Routine testing involves electrical, thermal, and safety checks on every unit as per IS 1180 and IEC 60076 standards. Type testing comprises additional comprehensive tests on selected units to assess overall design performance, mechanical strength, and compliance with regulatory requirements, ensuring dependable operation in the field.

Q: How does the Dyn11 winding connection benefit the installation?

A: The Dyn11 winding configuration offers superior phase shift and improved fault tolerance, which helps manage unbalanced loads and reduces issues from harmonics. This enhances the stability and efficiency of the industrial power network, making it a preferred choice for sensitive electrical systems.

Q: What are the main material and construction features that ensure durability?

A: Crafted from high-grade silicon steel for the core and electrolytic copper for windings, the transformer offers excellent magnetic properties and electrical conductivity. The anti-corrosive epoxy powder coating and robust skid or wheel mounting enhance resistance to environmental stresses, ensuring lasting performance.